G-W7K9HBSZ9E google-site-verification=0lV03ZaaYlPJ19oOujeuRuaa4MouRBN_E7hROmtPtKU

ONE-Step™ Luciferase Assay System - 500 ml | 60690-5

(No reviews yet) Write a Review
SKU:
412-60690-5
Weight:
1.00 KGS
€7,095.00
Frequently bought together:

Description

ONE-Step™ Luciferase Assay System - 500 ml | 60690-5 | Gentaur US, UK & Europe Disrtribition

Category: Cell Signaling/Media & Reagents

Application: • Monitor firefly (Photinus pyralis) luciferase activity in cultured mammalian cells. • High-throughput screening using luciferase reporter cell lines

Background: Luciferase is the general term given to a class of oxidative enzymes that catalyze reactions that give off light, a process known as bioluminescence. In biology, researchers can take advantage of this reaction and use it as a readout for various biological processes. This has perhaps been exploited most in luciferase reporter cell lines where a promoter region from a gene of interest is placed immediately upstream of the coding sequence for luciferase. In this system, transcriptional activation of the gene of interest leads to a level of luciferase expression that is proportional to the level of gene activation.
The level of activation is then assessed by lysing the cells and adding the luciferase substrate, D-luciferin. Using the One-Step Luciferase Assay System from BPS Bioscience, this is accomplished in a single step as the lysis buffer has been formulated with D-luciferin. After a brief incubation period, bioluminescence is read on a luminometer.

Description: The One-Step Luciferase Assay System is designed to be used for high-throughput, sensitive quantitation of firefly luciferase activity in mammalian cell culture. The reagent consists of two components, a Luciferase Reagent Buffer (Component A) and Luciferase Reagent Substrate (Component B). Component A and Component B are combined to form a working solution that contains all the necessary components for cell lysis and luciferase quantitation. This assay system has several features:
• Sensitive - highly sensitive detection of firefly luciferase activity.
• Stable - the signal output is stable for more than two hours, providing flexibility with regard to incubation time
• Convenient - simple one-step, homogeneous protocol.
• High-throughput - one-step homogeneous protocol minimizes handling steps to support high-throughput screening applications
• Compatibility - works well with a variety of common media containing 0-10% serum and phenol red.
• Instrumentation - does not require a luminometer with injectors.

Product Type: Reagent

Shippement Condition: -20°C (gel packs or dry ice)

View AllClose